Alarm Management

ISA-18.2 & API RP 1167 Alarm Management Consulting

Expert remote Quick Audits and rationalization for Honeywell Experion, Yokogawa Centum VP, Emerson DeltaV, and other DCS platforms. Achieve 80–92% nuisance alarm reduction.

Get a Free Quick Audit →

Professional Alarm Management for DCS Systems

We specialize in ISA-18.2 compliant alarm rationalization, nuisance alarm reduction, and advanced alarm management consulting for Honeywell Experion, Yokogawa Centum VP, Emerson DeltaV, and legacy DCS platforms.

Our Simple, Secure & Low-Risk Rationalization Process

From your historian data to a clear, actionable report — all handled remotely with your complete data security and confidentiality protected.

1

Historian Data Export

You export a standard alarm history file from your DCS historian. No special tools or access required from us.

2

Secure, Encrypted Upload

You upload the file through our secure, encrypted portal. We sign a mutual NDA before any data is shared.

3

Remote Analysis & Report

We analyze the data in a secure environment and deliver a prioritized report with bad-actor identification, recommended fixes, and an implementation roadmap.

When You Receive the Report

Your internal team or chosen System Integrator can then implement the changes directly. Result: 80–92% nuisance alarm reduction, improved operator focus, and thousands of dollars saved versus a full-time contractor.

Sample Quick Audit Report — Top Bad Actors

Realistic example of the professional deliverable you receive from a 2–4 week ROI Quick Audit (Honeywell Experion platform — customer information redacted). Projected 82–91% nuisance alarm reduction and $50K–$100K+ savings versus a full-time contractor.

Alarm TagDescriptionPriorityAlarms/Day% TotalTypeRecommended Fix
LAH-12045LNG Tank 1 Level HighHigh38519%ChatteringAdd 8-sec delay + deadband
PAH-23456Boil-Off Gas Compressor Discharge Pressure HighMed1427%StaleLogic suppression when offline
FAH-34567Fire & Gas Detector 12A ActivationHigh985%DuplicateConsolidate redundant detectors
LAHH-45678LNG Tank 2 Level High-HighHigh764%Flood during startupDynamic suppression during startup
TAH-56789HP Fuel Gas Temperature HighMed653%ChatteringIncrease deadband to 5°F
PAHH-67890MR Compressor Suction Pressure High-HighHigh583%StaleSuppression when in recycle mode
LAH-78901Condensate Tank Level HighMed523%FloodDelay + mode-based suppression
FAHH-89012Fire Zone 3 Detector ActivationHigh472%DuplicateLogic consolidation
TAHH-90123Boil-Off Gas Temperature High-HighHigh412%ChatteringDeadband + delay
PAH-01234LP Fuel Gas Pressure HighMed382%StaleSuppression logic when idle

Full deliverables include complete bad-actor analysis and prioritization, an ISA-18.2 / API RP 1167 rationalization roadmap, an implementation plan for alarm shelving and dynamic suppression, a cross-system coordination matrix (SIS, PLCs, SCADA), ready-to-use KPI dashboards, and a phased implementation roadmap.

"The ROI Quick Audit gave us exactly what we needed — a clear, prioritized plan and 80%+ alarm reduction roadmap — at a fraction of the cost and time of a long-term contractor."

— Operations Engineering Manager, Major LNG Facility

Start your secure alarm Quick Audit

Turn alarm floods into a calm, meaningful environment your operators can trust.

Start Your Quick Audit →